• Users Online: 148
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2021  |  Volume : 33  |  Issue : 1  |  Page : 1-5

Evaluation of successful and failed filtering blebs after trabeculectomy using anterior segment optical coherence tomography


1 Department of Ophthalmology, Faculty of Medicine, Yuzuncu Yil University, Van, Turkey
2 Department of Ophthalmology, Beyoglu Eye Research and Training Hospital, Istanbul, Turkey

Correspondence Address:
Serek Tekin
Department of Ophthalmology, Faculty of Medicine, Yuzuncu Yil University, 65080, Tusba, Van
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JOCO.JOCO_112_20

Rights and Permissions

Purpose: To evaluate filtering bleb characteristics using anterior segment optical coherence tomography (AS-OCT) and analyze correlations between these parameters and intraocular pressure (IOP). Methods: The study included 54 eyes of 43 patients who underwent trabeculectomy with mitomycin-C. The patients were divided into two groups based on mean postoperative IOP. The criterion for surgical success was mean unmedicated postoperative IOP ≤18 mmHg. Patients with IOP values >18 mmHg were prescribed anti-glaucoma drops and classified as a surgical failure. All patients underwent AS-OCT, and maximum bleb height, maximum bleb wall thickness, and maximum fluid-filled cavity height were measured. AS-OCT bleb parameters were compared between the successful and failed groups. Results: Of the 54 eyes, 37 (68.5%) were in the successful group, and 17 (31.5%) were in the failed group. Mean preoperative IOP values in the successful and failed groups were 26.9 ± 6.5 mmHg and 22.9 ± 4.9 mmHg, preoperatively, versus postoperative values of 13.3 ± 2.1 mmHg and 22.8 ± 2.8 mmHg, respectively. Mean postoperative follow-up time was 17.4 ± 9.5 months in the successful group and 19.1 ± 10.1 months in the failed group (P = 0.22). In the successful and failed groups, mean bleb height was 1473.7 ± 150.6 μm and 1165.4 ± 217 μm (P < 0.001), bleb wall thickness was 670.5 ± 119.9 μm and 538.8 ± 144.3 μm (P = 0.001), and fluid-filled cavity height was 736.5 ± 196.8 μm versus 532.5 ± 226.2 μm (P = 0.001), respectively. Conclusions: The results of this study showed that higher AS-OCT values for bleb height, wall thickness, and fluid-filled cavity height were associated with greater functional success. These parameters may be helpful in determining bleb functionality.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed411    
    Printed16    
    Emailed0    
    PDF Downloaded70    
    Comments [Add]    

Recommend this journal