• Users Online: 237
  • Print this page
  • Email this page


 
 Table of Contents  
LETTER TO EDITOR
Year : 2020  |  Volume : 32  |  Issue : 4  |  Page : 427

Comment on the article: Management of upside-down descemet membrane endothelial keratoplasty: A case series


Department of Cornea, Anand Eye Institute, Hyderabad, Telangana, India

Date of Submission03-May-2020
Date of Decision16-May-2020
Date of Acceptance04-Jun-2020
Date of Web Publication12-Dec-2020

Correspondence Address:
Arjun Srirampur
Department of Cornea, Anand Eye Institute, Habsiguda, Hyderabad - 500 007, Telangana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JOCO.JOCO_173_20

Rights and Permissions

How to cite this article:
Srirampur A. Comment on the article: Management of upside-down descemet membrane endothelial keratoplasty: A case series. J Curr Ophthalmol 2020;32:427

How to cite this URL:
Srirampur A. Comment on the article: Management of upside-down descemet membrane endothelial keratoplasty: A case series. J Curr Ophthalmol [serial online] 2020 [cited 2021 Jan 20];32:427. Available from: http://www.jcurrophthalmol.org/text.asp?2020/32/4/427/303197



Dear Editor,

I have read with interest the article by Bardan et al. on “Management of upside-down Descemet membrane endothelial keratoplasty: A case series” .[1]

I would like to add a few relevant points pertaining to this article. The authors have reported upside-down Descemet membrane endothelial keratoplasty (DMEK) grafts to be 5 out of 37 eyes (13%), which is in concurrence to the reported incidence of 0–18%. In case 1, the graft detachment was confirmed on the postoperative day 5, but the subsequent intervention was not taken up until day 20. The reasons for the delay in the intervention were not specified. Grafts detached for a prolonged period are known to show fibrosis and graft shrinkage, which do not allow late successful management.[2]

In addition, it would have been more informative if the type of tissue preservation (organ culture vs. cold preservation) and the relationship between descemetorhexis and graft sizes were mentioned in the article. This is of more relevance as these factors can influence the attachment of the graft. Furthermore, the donor age should have been mentioned in all five cases.[3]

Apart from the methods described in the article to identify DMEK scroll orientation like Moutsouris sign, peripheral marks, “S” or “F” stamps, the use of slit beam, and the use of intraoperative optical coherence tomography, we can also use a endoilluminator-assisted transcorneal illumination at the limbus.[4] By holding the endoilluminator tip tangentially at the limbus, this helps to identify the correct graft orientation, especially in edematous, hazy corneas where a DMEK is performed. The tangential light provided by the endoilluminator highlights the details of the graft, such as graft position, folds, and the orientation of the Descemet membrane in relation to the corneal stroma. The tip of the light probe is moved around the limbus while it is focused tangentially to allow a good visualization and have a three-dimensional perception. A graft with its edges scrolling toward the recipient stroma (upward) is an important sign to know that the tissue is oriented the “right way up” . Visualization can be further enhanced by switching off the room and microscope lights. Using endoilluminator, the graft is seen to be oriented the right way up, so the edges curl upward and then centered under the stripped recipient site, after which an air bubble is injected under the graft to float it up against the overlying stroma. This also aids the surgeon in reducing the operating time considerably, thereby decreasing the graft manipulation and subsequent endothelial damage. Thus, this simple technique also helps in preventing upside-down DMEK grafts during the surgery.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Bardan AS, Goweida MB, El Goweini HF, Liu CS. Management of upside-down Descemet membrane endothelial keratoplasty: A case series. J Curr Ophthalmol 2020;32:142-8.  Back to cited text no. 1
  [Full text]  
2.
Fernández López E, Baydoun L, Gerber-Hollbach N, Dapena I, Liarakos VS, Ham L, et al. Rebubbling techniques for graft detachment after descemet membrane endothelial keratoplasty. Cornea 2016;35:759-64.  Back to cited text no. 2
    
3.
Leon P, Parekh M, Nahum Y, Mimouni M, Giannaccare G, Sapigni L, et al. Factors associated with early graft detachment in primary descemet membrane endothelial keratoplasty. Am J Ophthalmol 2018;187:117-24.  Back to cited text no. 3
    
4.
Jacob S, Agarwal A, Agarwal A, Narasimhan S, Kumar DA, Sivagnanam S. Endoilluminator-assisted transcorneal illumination for descemet membrane endothelial keratoplasty: Enhanced intraoperative visualization of the graft in corneal decompensation secondary to pseudophakic bullous keratopathy. J Cataract Refract Surg 2014;40:1332-6.  Back to cited text no. 4
    




 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
References

 Article Access Statistics
    Viewed190    
    Printed18    
    Emailed0    
    PDF Downloaded26    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]